Full Coverage Drum Heaters (FGDH/FGPDH/FGDDC)
BriskHeat full-coverage drum heaters provide a highly efficient, all-in-one heating and insulation solution engineered to wrap completely around industrial containers. By combining high-performance heating elements with a built-in thermal insulation blanket, this system significantly accelerates heat-up times and maximizes energy efficiency by keeping heat directed entirely into the vessel. This rugged, wrap-around system is ideal for a wide range of industrial applications, including viscosity control, freeze protection, process temperature maintenance, melting of solids, and thermal mixing.
- Precise Digital Control: Equipped with an easy-to-program digital temperature controller, adjustable up to 160°F (71°C) for poly/plastic containers or up to 450°F (232°C) for metal drums.
- Maximum Operational Safety: Features a fully grounded, patented 360° heating element architecture that meets National Electrical Code (NEC) 427.23 standards for safe industrial deployment.
- Industrial-Grade Construction: Designed with a 1.0 in (25 mm) thick high-density fiberglass insulation layer enclosed in a durable, moisture- and chemical-resistant outer cloth shell.
-
Available Sizes: Models tailored to securely fit standard 5, 16, 30, and 55-gallon industrial drums and pails.
Please complete all selections above to add this item to cart.
Since 1949
Outer Material: Silicone impregnated cloth
Insulation: 1.0 in (25 mm) thick fiberglass
Closure Method: Hook and loop fasteners
Maximum Exposure Temperature: 500°F (260°C)
IP Rating: IP4X
Operating Temperature:
- 50° to 450°F (10° to 232°C) for Metal Drums
- 50° to 160°F (10° to 71°C) for Poly Drums
Digital Control: On/off controller. Display is either °F or °C depending on model
Heated Area:
- 55 and 30 gallon size (208 and 114 Liter): Lower two thirds
- 15 and 5 gallon size (61 and 19 Liter): Lower third
Heating Element: 360° grounded heating element for your safety
Dielectric Strength: Over 2000 volts
Power Cord: 6 ft (1.8 m) long:
- 120 VAC: 3-prong grounded plug (NEMA 5-15P)
- 240 VAC: 3-prong grounded plug (NEMA 6-15P) or crimped ferrule leads
Models with crimped ferrule leads
Viscosity Control
Freeze Protection
Temperature Maintenance
Melting of Solids
Thermal Mixing
Single Zone for Metal Drums - FGDH Series
| 120 VAC with °F display and NEMA 5-15P Plug | 240 VAC with °F display and NEMA 6-15P Plug | 240 VAC with °C display and Crimped Ferrule Leads | Insulator Only | Size gal (l) | Diameter in (mm) | Height in (mm) | Number of Zones | Total Wattage |
| FGDHC55120D | FGDHC55240DV | FGDHC55240DCV | FGDI55V | 55 (208) | 22.3 (566) | 36.4 (924) | 1 | 1600 |
| FGDHC30120D | FGDHC30240D | FGDHC30240DC | FGDI30 | 30 (114) | 18.6 (473) | 29.5 (749) | 1 | 1160 |
| FGDHC15120D | FGDHC15240D | FGDHC15240DC | FGDI15 | 16 (61) | 14.0 (355) | 26.7 (678) | 1 | 870 |
| FGDHC5120D | FGDHC5240D | - | - | 5 (19) | 11.1 (282) | 13.5 (343) | 1 | 550 |
Single Zone for Poly Drums - FGDH Series
| 120 VAC with °F display and NEMA 5-15P Plug | 240 VAC with °F display and NEMA 6-15P Plug | 240 VAC with °C display and Crimped Ferrule Leads | Insulator Only | Size gal (l) | Diameter in (mm) | Height in (mm) | Number of Zones | Total Wattage |
| FGPDHC55120D | FGPDHC55240D | FGPDHC55240DCV | FGDI55V | 55 (208) | 22.3 (566) | 36.4 (924) | 1 | 770 |
| FGPDHC30120D | - | - | FGDI30 | 30 (114) | 18.6 (473) | 29.5 (749) | 1 | 553 |
Dual Zone for Poly Drums - FGDDC Series
| 240 VAC with °F display and NEMA 6-15P Plug | 240 VAC with °C display and Crimped Ferrule Leads | Size gal (l) | Diameter in (mm) | Height in (mm) | Number of Zones | Total Wattage |
| FGDDC55240DV | FGDDC55240DCV | 55 (208) | 22.3 (566) | 36.4 (924) | 2 | 3200 (1600 per zone) |
Catalog/Specifications Sheet
Instruction Manuals
Q: What types of container heaters are available?
A: Common container heater types include:
- Full coverage drum heaters
- Full-coverage IBC tote tank heaters
- Pail heaters
- Silicone drum and pail heaters
Q: What are container heaters used for?
A: Container heaters are commonly used to:
- Viscosity control
- Maintain process temperatures
- Protect temperature-sensitive products during storage
Q: How do container heaters improve viscosity control?
A: Heating materials to their recommended temperatures can lower viscosity, making liquids easier to pump, mix, transfer, and dispense while improving process efficiency.
Q: Can container heaters be used for hazardous locations?
A: Our ATEX Drum, Tote, and Gas Cylinder container heaters are designed and certified for hazardous locations. It is always important to verify approvals and certifications before installation in hazardous environments.
Q: Can container heaters prevent materials from freezing?
A: Yes. Container heaters are commonly used to maintain temperatures above freezing, helping protect materials from solidification, crystallization, or freeze damage during storage and use.
Q: How do I properly store my drum & tote heater?
A: We suggest that you lay your drum heater on a flat surface when not in use.
Q: What lengths and widths do tote tank heaters fit?
A: Any footprint between 40” x 40” (1016mm x 1016mm) and 48” x 48” (1219mm x 1219mm).
Q: Are there safety features for tote tank heaters like high-limit thermostats?
A: Yes, the wrap-arounds have built-in 195°F (91°C) manual reset high-limit thermostats and are grounded.
Q: Do cylinder warmers have adjustable built-in controllers?
A: No, the heaters are designed to keep the cylinders warm and temperatures will vary depending on environmental conditions. GCW and HCW heaters are built with self-regulating heat trace meaning they automatically adjust temperature depending on application and ambient conditions.
Q: Are cylinder warmers plug-and-play?
A: The 120V GCW models include a plug, but other models have ferrule-crimped leads.