High-Temperature Constant-Wattage Heating Cable (KK) - BriskHeat



High-Temperature Constant-Wattage Heating Cable (KK)

High-Temperature Constant-Wattage Heating Cable (KK) - BriskHeat
ORDERING OPTIONS
Request a quote
  • Ideal for a wide range of high temperature extreme flexibility applications up to 500°F (260°C)
  • Constant Watt - precise and constant temperature output regardless of ambient and surface temperatures.
  • Ideal heating cable for long run applications.
  • Extreme flexibility construction:  Thin profile construction with tinned copper over braid.
  • Easily installed around most piping and equipment.
  • Can be cut-to-length and terminated at the job site.
  • Approvals for ordinary and hazardous area environments.
  • Maximum exposure temperature is 500°F (260°C)
  • Available in 4, 8, 12, and 18 watts/ft (13, 26, 39, and 59 watts/m)
  • Available in voltages 120, 208, 240, 277, and 480VAC
  • Circuit lengths up to 1,240ft (378m)
    • Ordinary Locations
    • Hazardous Locations:
      • Class I Division 2 Groups B, C, D
      • Class II Division 2 Groups F, G
      • Class III Division 2
  • Moisture, chemical, flame, and radiation resistant
  • 12AWG bus wires
  • Dimensions 0.15" x 0.25" (4 x 6mm)
  • 30 lb. (14kg) per 500-foot (152m) spool

Approval valid only when used with appropriate heating cable and installation accessories, and installed in accordance with all applicable instructions, codes, and regulations.

 

  • High-Range process temperature control for food and chemical processing facilities
  • Hot water lines
  • Fire protection systems
  • Fuel oil
  • Condensate return
  • Lines periodically purged with 250 psig steam

Maximum Circuit Length in ft (m)

Cable

120VAC

208VAC

240VAC

277VAC

480VAC

4 watts / ft
(13 watts / m)

480
(146)

830
(253)

960
(293)

1110
(338)

1920
(585)

8 watts / ft
(26 watts / m)

240
(73)

415
(127)

480
(146)

555
(169)

960
(293)

12 watts / ft
(39 watts / m)

160
(49)

277
(85)

320
(98)

370
(113)

640
(195)

18 watts / ft
(59 watts / m)

105
(32)

185
(56)

215
(65)

245
(75)

425
(130)

Circuit Module Length in ft (m)

Cable

120VAC

208VAC

240VAC

277VAC

480VAC

4 watts / ft
(13 watts / m)

4.0
(1.2)

4.0
(1.2)

4.0
(1.2)

4.0
(1.2)

8.0
(2.4)

8 watts / ft
(26 watts / m)

2.0
(0.6)

4.0
(1.2)

4.0
(1.2)

4.0
(1.2)

6.0
(1.8)

12 watts / ft
(39 watts / m)

2.0
(0.6)

4.0
(1.2)

4.0
(1.2)

4.0
(1.2)

7.0
(2.1)

18 watts / ft
(59 watts / m)

1.75
(0.5)

3.0
(0.9)

3.5
(1.1)

4.0
(1.2)

5.5
(1.7)

Note: when ordering, please allow a minimum of 1 module length extra for terminations.

  • Constant-Wattage cable uses a fixed resistance wire wrapped around two main conductors (bus wires).  At specific intervals the insulation is removed from the bus wires, forming the Contact Module Points. 
  • These Contact Module Points are staggered along the length of the cable.  This creates consistent heating circuits known as the Module Length.  When power is applied to the bus wires each complete Module Length heats at the rated wattage output. 
  • The incomplete Module Lengths, at the beginning and end of each cable, do not heat.  This allows the “Cold” ends to be safely placed inside of a controller or junction box.

 

This product requires a temperature controller for safe operation

Click Here to find a temperature controller or Click Here to contact the factory direct for assistance

Accessories

Customers Who Viewed This Were Also Interested In

Don't see your size or option? Have a question about which BriskHeat product is right for you? Need Application assistance? Contact Us. We are here to help!

Monday - Friday
8:00am - 5:00pm EST
United States & Canada
1-800-848-7673
Worldwide
1-614-294-3376