Cloth Heating Jackets XtremeFLEX® Heating Tapes and Cords Silicone Rubber Heating Blankets Drum / Pail Heaters IBC / Tote Tank Heaters Gas Cylinder Warmers Hopper Heating Systems Self-Regulating Heating Cable Constant-Wattage Heating Cable Mantle Heaters Resistance Wire Temperature Controllers Hazardous-Area Heaters and Controls Hot Bonders and Curing Blankets

Our Products

BriskHeat 

FE General Purpose Constant-Wattage Heating Cable


Click to Enlarge

 

Click to Enlarge

Product Highlights

Temperatures up to 400°F (204°C)

Power remains constant regardless of temperature

Can be cut-to-length at job site

Ideal for a wide range of general purpose applications

Specifications

TEFLON® is a registered Trademark of DuPont used under license.

Approvals

 

Ordinary Locations
Hazardous Location (T3 rated):
Class I Division 2 Groups B, C, D
Class II Division 2 Groups F, G
Class III Division 2

, Ordinary locations (120 and 240VAC)

Approval valid only when used with appropriate heating cable and installation accessories, and installed in accordance with all applicable instructions, codes, and regulations.

Maximum Circuit Length in ft (m)

Cable 120VAC 208VAC 240VAC 277VAC 480VAC
3 watts / ft
(10 watts / m)
360
(110)
625
(191)
720
(220)
N/A 1440
(439)
5 watts / ft
(16 watts / m)
275
(84)
477
(145)
550
(168)
N/A 1100
(335)
8 watts / ft
(26 watts / m)
220
(67)
381
(116)
440
(134)
508
(155)
880
(268)
12 watts / ft
(39 watts / m)
180
(55)
312
(95)
360
(110)
416
(127)
720
(220)

Circuit Module Length in ft (m)

Cable 120VAC 208VAC 240VAC 277VAC 480VAC
3 watts / ft
(10 watts / m)
2.0
(0.6)
4.0
(1.2)
4.0
(1.2)
N/A 8.0
(2.4)
5 watts / ft
(16 watts / m)
2.0
(0.6)
4.0
(1.2)
3.0
(0.9)
N/A 6.0
(1.8)
8 watts / ft
(26 watts / m)
2.0
(0.6)
4.0
(1.2)
4.0
(1.2)
4.0
(1.2)
6.0
(1.8)
12 watts / ft
(39 watts / m)
2.0
(0.6)
6.0
(1.8)
360
(110)
4.0
(1.2)
4.0
(1.2)

Note: when ordering, please allow a minimum of 1 module length extra for terminations.

 

FE General Purpose Constant-Wattage Heating Cable Specification Sheet

Ordering Information

Part Number Matrix

 

Connection / Termination Kits

Part Number Kit Enough to Complete
FECABUC Universal Connection / Termination Kit Two end terminations and one input connection, or one power input splice. Note: Requires a double hub junction box.
FECABKC Lead / End Seal Kit Five lead and end terminations.
FECABSK Splice Kit One in line splice or one tee splice. Note: Requires pipe standoff, pipe straps, single hub junction box, and RTV sealant.
FECABLP Lead Termination Kit One lead termination.
FECABEP End Termination Kit One end termination.

 

FE Connection / Termination Kit Specification Sheet

Temperature Controller

A temperature controller is required for this product. Check out temperature controller section for a complete selection of temperature controllers.

Accesories

Adhesive Tape

Helps to isolate the cable from the insulation and provides intimate contact with surface to be heated.

Part Number Description
PSAT36 Pressure Sensitive Fiberglass Adhesive Tape
0.5" x 108' (13mm x 38m)
Temperature limit: 350°F (176°C)
 
AAT260
AAT2180
Aluminum Adhesive Tape
2" x 180' (51mm x 55m) / Temperature limit: 350°F (176°C)
2" x 180' (51mm x 55m) / Temperature limit: 550°F (288°C)

 

Caution Label

Required by code for every 100ft (3m) of pipe.

Part Number Description
BCLCAB Electrical heat trace warning label. Required by code for every 10ft (3m) of pipe.

 

Heat Conductive Putty

Used to fill voids between cable and pipe surface.

Part Number Description
 
HCP1
HCP3
Heat Conductive Putty. Used to fill voids between cable and pipe surface.
1 lb. (0.5kg)
3 lb. (1.4kg)

 

Monitor Light Kit

Provides a continuity check at the termination end of a cable circuit.

Part Number Description
MLK1001 Single hub; 120VAC
MLK2001 Single hub; 240VAC
MLK1002 Double hub; 120VAC
MLK2002 Double hub; 240VAC
MLBCAB001 120VAC replacement bulb
40180 240VAC replacement bulb

 

Pipe Reducer

Part Number Description
BPRCAB010 Adapts 0.75" NPT male to 1" NPT female

 

Pipe Standoff

Cast aluminum fitting.

Part Number Description
PSOCAB010 1.00" thread
PSOCAB075 0.75" thread

 

Pipe Strap

Stainless steel pipe straps used to secure pipe standoff to pipe.

Part Number Description
BPSCAB2-6 Stainless steel pipe straps used to secure pipe standoff to pipe.
Adjustable from 2" to 6" (51 x 152mm)

 

RTV Sealant

Silicone sealant used to seal lead pouches, end pouches, and pipe standoffs.

Part Number Description
RTV3.0 Silicon sealant used to seal lead pouches, end pouches, and pipe standoffs. 3 oz. (89ml)

 

Support

Documents

Click Here to Go Back to the Heating Cable Main Page

BriskHeatSave to Favorites