About Us|
Products|
Applications|
Industries|
News|
Distributors/Reps|
Contact Us|
Personal Assistant

  Login       Shopping Cart (0)    Your Account
Language:
Currency:
VAT Mode:
ProductsHeating Cable → FE General Purpose Constant-Wattage Heating Cable

Bookmark and Share

Products Header      

BriskHeat Logo

FE General Purpose Constant-Wattage Heating Cable

Product Highlights

checkmark Temperatures up to 400oF (204oC)

checkmark Power remains constant regardless of temperature

checkmark Can be cut-to-length at job site

checkmark Ideal for a wide range of general purpose applications

  • Mid-range process temperature control for food and chemical processing
  • Water lines
  • Fire protection systems
  • Fuel oil
  • Condensate return
  • Hot water lines
  • Lines periodically purged with 250 psig steam

Specifications

  • Maximum exposure temperature is 400oF (204oC)
  • Moisture, chemical, flame, and radiation resistant
  • 12AWG bus wires
  • Dimensions 0.2" x 0.3" (5 x 8mm)
  • 40 lb. (18kg) per 500-foot (152m) spool

TEFLON® is a registered Trademark of DuPont used under license.

Approvals

 

Ordinary Locations
Hazardous Location (T3 rated):
Class I Division 2 Groups B, C, D
Class II Division 2 Groups F, G
Class III Division 2

Ordinary locations (120 and 240VAC only)      RoHSREACH

Approval valid only when used with appropriate heating cable and installation accessories, and installed in accordance with all applicable instructions, codes, and regulations.

Maximum Circuit Length in ft (m)

Cable120VAC208VAC240VAC277VAC480VAC
3 watts / ft
(10 watts / m)
360
(110)
625
(191)
720
(220)
N/A1440
(439)
5 watts / ft
(16 watts / m)
275
(84)
477
(145)
550
(168)
N/A1100
(335)
8 watts / ft
(26 watts / m)
220
(67)
381
(116)
440
(134)
508
(155)
880
(268)
12 watts / ft
(39 watts / m)
180
(55)
312
(95)
360
(110)
416
(127)
720
(220)

Circuit Module Length in ft (m)

Cable120VAC208VAC240VAC277VAC480VAC
3 watts / ft
(10 watts / m)
2.0
(0.6)
4.0
(1.2)
4.0
(1.2)
N/A8.0
(2.4)
5 watts / ft
(16 watts / m)
2.0
(0.6)
4.0
(1.2)
3.0
(0.9)
N/A6.0
(1.8)
8 watts / ft
(26 watts / m)
2.0
(0.6)
4.0
(1.2)
4.0
(1.2)
4.0
(1.2)
6.0
(1.8)
12 watts / ft
(39 watts / m)
2.0
(0.6)
6.0
(1.8)
360
(110)
4.0
(1.2)
4.0
(1.2)

Note: when ordering, please allow a minimum of 1 module length extra for terminations.

 

PDF FE General Purpose Constant-Wattage Heating Cable Specification Sheet

Ordering Information

Part Number Matrix

 

Connection / Termination Kits

Part NumberKitEnough to Complete
FECABUCUniversal Connection / Termination KitTwo end terminations and one input connection, or one power input splice. Note: Requires a double hub junction box.
FECABKCLead / End Seal KitFive lead and end terminations.
FECABSKSplice KitOne in line splice or one tee splice. Note: Requires pipe standoff, pipe straps, single hub junction box, and RTV sealant.
FECABLPLead Termination KitOne lead termination.
FECABEPEnd Termination KitOne end termination.

 

PDF FE Connection / Termination Kit Specification Sheet

Temperature Controller

A temperature controller is required for this product. Check out temperature controller section for a complete selection of temperature controllers.

Accesories

Adhesive Tape

Helps to isolate the cable from the insulation and provides intimate contact with surface to be heated.

Part NumberDescription
PSAT36Pressure Sensitive Fiberglass Adhesive Tape
0.5" x 108' (13mm x 38m)
Temperature limit: 350oF (176oC)
 
AAT260
AAT2180
Aluminum Adhesive Tape
2" x 180' (51mm x 55m) / Temperature limit: 350oF (176oC)
2" x 180' (51mm x 55m) / Temperature limit: 550oF (288oC)

 

Caution Label

Required by code for every 100ft (3m) of pipe.

Part NumberDescription
BCLCABElectrical heat trace warning label. Required by code for every 10ft (3m) of pipe.

 

Heat Conductive Putty

Used to fill voids between cable and pipe surface.

Part NumberDescription
 
HCP1
HCP3
Heat Conductive Putty. Used to fill voids between cable and pipe surface.
1 lb. (0.5kg)
3 lb. (1.4kg)

 

Monitor Light Kit

Provides a continuity check at the termination end of a cable circuit.

Part NumberDescription
MLK1001Single hub; 120VAC
MLK2001Single hub; 240VAC
MLK1002Double hub; 120VAC
MLK2002Double hub; 240VAC
MLBCAB001120VAC replacement bulb
40180240VAC replacement bulb

 

Pipe Reducer

Part NumberDescription
BPRCAB010Adapts 0.75" NPT male to 1" NPT female

 

Pipe Standoff

Cast aluminum fitting.

Part NumberDescription
PSOCAB0101.00" thread
PSOCAB0750.75" thread

 

Pipe Strap

Stainless steel pipe straps used to secure pipe standoff to pipe.

Part NumberDescription
BPSCAB2-6Stainless steel pipe straps used to secure pipe standoff to pipe.
Adjustable from 2" to 6" (51 x 152mm)

 

RTV Sealant

Silicone sealant used to seal lead pouches, end pouches, and pipe standoffs.

Part NumberDescription
RTV3.0Silicon sealant used to seal lead pouches, end pouches, and pipe standoffs. 3 oz. (89ml)

 

Support

Documents
Click here to view larger image


Show Picture 1Show Picture 2Show Picture 3

Click here to view larger image


 E-mail this product to a friend



 


KE Harsh Environment Constant-Wattage Heating Cable

KK High Temperature Constant-Wattage Heating Cable

SLCAB Self-Regulating Heating Cable

SLMCAB Mid-Temperature Self-Regulating Heating Cable

CTL Cut-to-Length Silicone Rubber Heating Tapes