| Overview | Centipede® Module | Operator Interface | Support / FAQ |
Centipede® Operator Interface
Product Highlights
|
|
![]() Click To Enlarge ![]() Click To Enlarge |
Specifications
General (CENTOPI-2 and CENTOEMOI)
- Monitors and edits up to 40 modules / zones; displays actual temperature, RTD status, set-point, high-limit alarm setting, and low-limit alarm setting
- Ability to change settings individually or globally across system
- Temperature setting range: 32° to 662°F (0° to 350°C)
- All temperatures displayed in °C
- Dry contact master alarm relay: Up to 277VAC, Up to 30VDC, 5A (normally open)
- Power consumption: 18 watts maximum with no modules; 50 watts maximum with 40 modules
- Output power: 12 volts DC at 3A through CAT5 communication cable
- Communication with modules: Modbus through CAT5 communication cable
- Communication with external computer: RS-232
- Maximum CAT5 communication cable length: 500ft (152m)
- Environment temperature range: 32° to 100°F (0° to 38°C)
- Storage exposure temperature range: 0° to 185°F (-18° to 85°C)
- Ambient humidity: 5 to 95% (non condensing)
CENTOPI-2: Operator Interface with Display Specifications
![]() |
![]() |
- Plug-and-play operator interface
- Universal input power: 100-240VAC, 47-440Hz; fuse-protected for safety
- Screen size: 4" x 3" (102mm x 76mm)
- 320 x 240 pixel LCD with keypad input
- Dual color LEDs; red and green. Red indicates fault
- Dimensions: 7 x 7 x 4" (178 x 178 x 102mm)
- Weight: 2.13lb (0.97kg)
, 
Process Control Equipment 29DP
CENTOEMOI: Operator Interface without Display Specifications
![]() |
![]() |
- No display; communicates with external computer via RS-232 port
- Input power: 12-24DC; requires Molex 6-pin power connector shell part #09-50-8063 and pins part #08-52-0072 (not included)
- Dimensions: 7.50 x 6.54 x 1.16" (191 x 166 x 29mm)
- Weight: 1lb (0.45kg)
- Four 0.19" (5mm) diameter holes for mouting
Centipede® Temperature Control System Specification Sheet
Ordering Information
| CENTOPI-2 | Centipede® Operator Interface: Includes a 25ft (7.6m) CAT5 communication cable and input power cable |
| CENTOEMOI | Centipede® Operator Interface without display |
Accessories
|
CAT5 Communication Cable
|
RTD Sensor
|
Data Logging PC Software
| Part Number | Description |
| SWCENTDLV100 | Centipede® Data Logger Version 1.0 |
Communicating with an External computer Instruction Manual
| Part Number | Description |
| 41082-01 | Communicating with an External computer Instructions |
Module Power Supply
| Part Number | Description |
| CENTPWR | 12-24VDC Power supply for modules with NEMA 5-15 plug. Required when operator interface is not used with module(s). |
Click here to see more BriskHeat® Temperature Control options















Monitors and edits a network of up to 40 modules / zones